Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(7)2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38612195

RESUMO

A new Mg-Zn-Zr-Ca alloy in a powder state, intended to be used for custom shaped implants, was obtained via a mechanical alloying method from pure elemental powder. Further, the obtained powder alloy was processed by a PBF-LB/M (powder bed fusion with laser beam/of metal) procedure to obtain additive manufactured samples for small biodegradable implants. A series of microstructural, mechanical and corrosion analyses were performed. The SEM (scanning electron microscopy) analysis of the powder alloy revealed a good dimensional homogeneity, with a uniform colour, no agglutination and almost rounded particles, suitable for the powder bed fusion procedure. Further, the PBF-LB/M samples revealed a robust and unbreakable morphology, with a suitable porosity (that can reproduce that of cortical bone) and without an undesirable balling effect. The tested Young's modulus of the PBF-LB/M samples, which was 42 GPa, is close to that of cortical bone, 30 GPa. The corrosion tests that were performed in PBS (Phosphate-buffered saline) solution, with three different pH values, show that the corrosion parameters have a satisfactory evolution comparative to the commercial ZK 60 alloy.

2.
Materials (Basel) ; 15(7)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35407893

RESUMO

The aim of the present paper is to apply the laser powder bed fusion process to a new biodegradable Mg-Zn-Zr-Ca alloy powder prepared via a mechanical alloying method from powder pure components. This additive manufacturing method is expected to allow for the obtaining of high biomechanical and biochemical performance. Various processing parameters for laser powder bed fusion are tested, with a special focus on laser energy density-E [J/mm3]-which is calculated for all experiment variants, and which represents an important processing parameter, dependent upon all the rest. The goal of all the trials is to find the most efficient schema for the production of small biodegradable parts for the medical domain, meaning the selection of optimal processing parameters. An important observation is that the most robust and homogeneous samples without cracks are obtained for lower values of the E, around 100 J/mm3. Thus, the most performant samples are analyzed by scanning electron microscopy, X-ray diffraction and by compression mechanical test.

3.
J Biomed Mater Res B Appl Biomater ; 107(5): 1483-1490, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30265783

RESUMO

To enhance their longevity, dental implants must be highly biocompatible and must have a low elastic modulus close to that of the bone. They must also possess a high superficial hardness and a high corrosion resistance. For these reasons, a recently developed low-modulus Ti-27Nb alloy with nontoxic elements was treated by gas nitriding at high temperature in this study. A very thin nitrided layer of 0.5 µm in thickness followed by an enriched nitrogen zone was observed. Consequently, a very high hardness evaluated at about 1800 HV was obtained in surface, which represents an increase of 4-5 times the hardness of the non-nitrided alloy. This superficial hardness was experimentally observed to decrease up to 800 nm in depth from the surface to the core. The low modulus of Ti-27Nb (evaluated at 55 GPa, which is twice lower than the commercially pure titanium) was not affected by the surface nitriding treatment. A better corrosion resistance was observed and a significant decrease in ion release rates for the nitrided alloy (ion release of 1.41 ng/cm2 compared to the 163.58 ng/cm2 obtained for the commercially pure titanium at pH = 7.48 in artificial Carter-Brugirard saliva). The cytocompatibility was not compromised and the cell viability performed on human osteoblasts, fibroblastic cells, and epithelial cells was enhanced on the nitrided surface in comparison with the non-nitrided surface. These combined properties make the nitrided Ti-27Nb alloy a good candidate for dental implant applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1483-1490, 2019.


Assuntos
Ligas , Implantes Dentários , Teste de Materiais , Titânio , Ligas/química , Ligas/farmacologia , Animais , Linhagem Celular Tumoral , Humanos , Camundongos , Nióbio/química , Nióbio/farmacologia , Titânio/química , Titânio/farmacologia
4.
Materials (Basel) ; 9(10)2016 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-28773939

RESUMO

A new superelastic Ti-23Hf-3Mo-4Sn biomedical alloy displaying a particularly large recovery strain was synthesized and characterized in this study. Its native passive film is very thick (18 nm) and contains very protective TiO2, Ti2O3, HfO2, MoO2, and SnO2 oxides (XPS analysis). This alloy revealed nobler electrochemical behavior, more favorable values of the corrosion parameters and open circuit potentials in simulated body fluid in comparison with commercially pure titanium (CP-Ti) and Ti-6Al-4V alloy taken as reference biomaterials in this study. This is due to the favorable influence of the alloying elements Hf, Sn, Mo, which enhance the protective properties of the native passive film on alloy surface. Impedance spectra showed a passive film with two layers, an inner, capacitive, barrier, dense layer and an outer, less insulating, porous layer that confer both high corrosion resistance and bioactivity to the alloy. In vitro tests were carried out in order to evaluate the response of Human Umbilical Vein Endothelial Cells (HUVECs) to Ti-23Hf-3Mo-4Sn alloy in terms of cell viability, cell proliferation, phenotypic marker expression and nitric oxide release. The results indicate a similar level of cytocompatibility with HUVEC cells cultured on Ti-23Hf-3Mo-4Sn substrate and those cultured on the conventional CP-Ti and Ti-6Al-4V metallic materials.

5.
Biomed Res Int ; 2015: 261802, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26583096

RESUMO

The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology.


Assuntos
Ligas/uso terapêutico , Osteoblastos/efeitos dos fármacos , Próteses e Implantes , Titânio/uso terapêutico , Ligas/química , Materiais Biocompatíveis , Interface Osso-Implante , Proliferação de Células/efeitos dos fármacos , Humanos , Teste de Materiais , Propriedades de Superfície , Titânio/química
6.
Mater Sci Eng C Mater Biol Appl ; 38: 127-42, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24656361

RESUMO

A new Ti-25Ta-5Zr alloy based only on non-toxic and non-allergic elements was elaborated in as-cast and thermo-mechanical processed, recrystallized states (XRD and SEM) in order to be used as candidate material for implant applications. Its long-term interactions with Ringer-Brown and Ringer solutions of different pH values and its cytocompatibility were determined. The thermo-mechanically processed alloy has nobler electrochemical behaviour than as-cast alloy due to finer microstructure obtained after the applied treatment. Corrosion and ion release rates presented the lowest values for the treated alloy. Nyquist and Bode plots displayed higher impedance values and phase angles for the processed alloy, denoting a more protective passive film. SEM micrographs revealed depositions from solutions that contain calcium, phosphorous and oxygen ions (EDX analysis), namely calcium phosphate. An electric equivalent circuit with two time constants was modelled. Cell culture experiments with MC3T3-E1 pre-osteoblasts demonstrated that thermo-mechanically processed Ti-25Ta-5Zr alloy supports a better cell adhesion and spreading, and enhanced cell proliferation. Altogether, these data indicate that thermo-mechanical treatment endows the alloy with improved anticorrosion and biological performances.


Assuntos
Ligas/química , Ligas/farmacologia , Técnicas Eletroquímicas/métodos , Fenômenos Mecânicos , Temperatura , Animais , Materiais Biocompatíveis/farmacologia , Líquidos Corporais/efeitos dos fármacos , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Corrosão , Cristalização , Espectroscopia Dielétrica , Eletricidade , Teste de Materiais , Camundongos , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Análise de Regressão , Soluções , Espectrometria por Raios X , Tantálio , Titânio , Difração de Raios X , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...